{"id":2970,"date":"2025-06-19T19:42:51","date_gmt":"2025-06-19T11:42:51","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-61386-21-2021-clause-10-4-10110-4-103-and-figure-103-bending-apparatus-for-metallic-and-composite-conduits\/"},"modified":"2025-06-24T17:16:40","modified_gmt":"2025-06-24T09:16:40","slug":"iec-61386-21-2021-klauzula-10-4-10110-4-103-i-rysunek-103-urzadzenie-do-giecia-przewodow-metalowych-i-kompozytowych","status":"publish","type":"post","link":"https:\/\/www.ledtestsystem.com\/pl\/produkty\/iec-61386-21-2021-klauzula-10-4-10110-4-103-i-rysunek-103-urzadzenie-do-giecia-przewodow-metalowych-i-kompozytowych\/","title":{"rendered":"IEC 61386-21: 2021 Klauzula 10.4.101 i 10.4.103 oraz rysunek 103 Urz\u0105dzenie do gi\u0119cia rur metalowych i kompozytowych"},"content":{"rendered":"<p>LS-B51M nadaje si\u0119 do test\u00f3w zginania przewod\u00f3w metalowych i kompozytowych. K\u0105t zginania wynosi 90\u00b0. Po te\u015bcie nale\u017cy sprawdzi\u0107, czy pr\u00f3bka ma p\u0119kni\u0119cia. Spe\u0142nia wymagania normy IEC 61386-21: 2021, punkt 10.4.101 i 10.4.103 oraz rysunek 103 (GB 20041.21, punkt 10.4 i rysunek 101), GB\/T14823.2, JG\/T3050 i ZBG33008.<\/p>\n<p><strong>Specyfikacje:<\/strong><br \/>\n- \u015arednica nominalna tulei pr\u00f3bki: 16, 20, 25 mm<br \/>\n- Promie\u0144 poziomy ko\u0142a formy: 48, 60, 75 mm<br \/>\n- Promie\u0144 gi\u0119cia k\u00f3\u0142: 84, 105, 131,25 mm<br \/>\n- Promie\u0144 ko\u0142a formy i rowka ko\u0142a gn\u0105cego: 8,1, 10,1, 12,6 mm<br \/>\n- \u015arednica rowka ko\u0142a gn\u0105cego: 24, 30, 37,5 mm<br \/>\n- K\u0105t gi\u0119cia pr\u00f3bki: 180\u00b0<br \/>\n- Wymiary ca\u0142kowite: 300x300x600mm<br \/>\n- Waga: oko\u0142o 25 kg<\/p>\n<p><div id=\"attachment_16850\" style=\"width: 592px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-16850\" decoding=\"async\" class=\"wp-image-16850 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-21-2021-Clause-10.4.10110.4.103-and-Figure-103.png\" alt=\"\" width=\"582\" height=\"570\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-21-2021-Clause-10.4.10110.4.103-and-Figure-103.png 582w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-21-2021-Clause-10.4.10110.4.103-and-Figure-103-400x392.png 400w\" sizes=\"auto, (max-width: 582px) 100vw, 582px\" title=\"\"><\/p>\n<p id=\"caption-attachment-16850\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 61386-21: 2021 Klauzula 10.4.101<\/span><\/p>\n<\/div>\n<div id=\"attachment_16849\" style=\"width: 594px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-16849\" decoding=\"async\" class=\"wp-image-16849 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-21-2021-Clause-10.4.10110.4.103.png\" alt=\"\" width=\"584\" height=\"118\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-21-2021-Clause-10.4.10110.4.103.png 584w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-21-2021-Clause-10.4.10110.4.103-400x81.png 400w\" sizes=\"auto, (max-width: 584px) 100vw, 584px\" title=\"\"><\/p>\n<p id=\"caption-attachment-16849\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 61386-21: 2021 Klauzula 10.4.103<\/span><\/p>\n<\/div>\n<div id=\"attachment_16847\" style=\"width: 600px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-16847\" decoding=\"async\" class=\"wp-image-16847 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-21-2021-Figure-103.png\" alt=\"\" width=\"590\" height=\"774\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-21-2021-Figure-103.png 590w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-21-2021-Figure-103-305x400.png 305w\" sizes=\"auto, (max-width: 590px) 100vw, 590px\" title=\"\"><\/p>\n<p id=\"caption-attachment-16847\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 61386-21:2021 Rysunek 103<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>LS-B51M is suitable for bending tests of metal and composite conduits. The bending angle is 90\u00b0. After the test, observe whether the sample has cracks. It complies with the requirements of IEC 61386-21: 2021 Clause 10.4.101&amp;10.4.103 and Figure 103 (GB 20041.21 Clause 10.4 and Figure 101 ), GB\/T14823.2, JG\/T3050 and ZBG33008. Specifications: \u2022\u00a0 Nominal diameter [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3492,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[664],"class_list":["post-2970","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls-b51m"],"_links":{"self":[{"href":"https:\/\/www.ledtestsystem.com\/pl\/wp-json\/wp\/v2\/posts\/2970","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestsystem.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestsystem.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/pl\/wp-json\/wp\/v2\/comments?post=2970"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestsystem.com\/pl\/wp-json\/wp\/v2\/posts\/2970\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/pl\/wp-json\/wp\/v2\/media\/3492"}],"wp:attachment":[{"href":"https:\/\/www.ledtestsystem.com\/pl\/wp-json\/wp\/v2\/media?parent=2970"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/pl\/wp-json\/wp\/v2\/categories?post=2970"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/pl\/wp-json\/wp\/v2\/tags?post=2970"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}