The PFS-80V100A Automotive Power Fail Simulator | Voltage Micro-interruption Generator is a product specially developed and produced to meet the wiring harness interruption (micro-interruption) test of power lines and signal lines. It simulates the interruption, plugging and unplugging of power lines and signal lines, and determines a common and reproducible evaluation basis.

ํ‘œ์ค€:
ISO16750-2-2023, IEC 62132-2 , IEC/EN 61000-4-20 , ISO 7637-2๏ผŒBMW GS 95003-2, Chrylser CS-11979, Fiat 9.90110, Ford EMC-CS-2009.1, GMW 3172, Hyundai Kia ES 95400-10, Hyundai Kia ES 96100-02, IVECO 16-2103, Mack Trucks 606GS15, Mitsubishi ES-X82010, PSA B21 7110, Volvo STD 515-003, Ford FMC 1278, BMW GS 95024-2-2, Jaguar JLR-EMC-CS, Tesla TS-0000425-05.

์• ํ”Œ๋ฆฌ์ผ€์ด์…˜:
Electrical performance testing of vehicle electronics; it can meet the test requirements of 12V/24V/48V system at the same time.

Characteristic:
โ€ข Can be controlled by the software
โ€ข Can cooperate with (0-80V) DC power supply to achieve test purposes;
โ€ข Breaking the waveform time to edit freely;
โ€ข High integration dual module combination;
โ€ข The signal line module can adapt to high -speed communication;
โ€ข The minimum drop time can be set 1ยตs;

Power Line Fail Test Interface

Power Line Fail Test Interface

Communication Line Fail Test Interface

Communication Line Fail Test Interface

์‚ฌ์–‘:

Interference Type Simulation power cable interruption, short circuit, insertion and other industrial conditions;
Power Cord Switch๏ผš
Power Switch 2 road switch: -DC+ power cord; -DC-ground wire
EUT Voltage ยฑ80V
EUT Max. Current 100A
S2 Leakage Resistance Open circuit, 0ฮฉ, 0.1ฮฉ, 1ฮฉ, 100ฮฉ
Current Direction Unidirectional
Switching Time ๏ผœ200ns
Rising Edge/Decrease Edge Realize the upper and lower edges of 200ns under the open circuit
Peak Current 400 A for 200 ms 1350 A for 1 ms
Automatic switch-off if I > 1,350 A
Interruption Time 1ฮผs~60s
Calibration Parts Optional
Signal Wire Switch:
Number of Channels 16 independent channels can be switched to each other
EUT Power Supply ยฑ50V DC/5A
Switching Type Automatic switch
Test Mode Support single roads, multi -road tests at the same time
Interruption time 1ฮผs~60s
Rising/down edge 100ฮฉ load up and down and also full meet <200ns at the same time
Safety Short -circuit protection function