{"id":2379,"date":"2025-06-19T19:35:13","date_gmt":"2025-06-19T11:35:13","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60884-1-clause-20-and-21-three-position-plug-socket-switch-life-tester\/"},"modified":"2025-06-27T11:04:01","modified_gmt":"2025-06-27T03:04:01","slug":"iec-60884-1-clause-20-and-21-three-position-plug-socket-switch-life-tester","status":"publish","type":"post","link":"https:\/\/www.ledtestsystem.com\/it\/prodotti\/iec-60884-1-clause-20-and-21-three-position-plug-socket-switch-life-tester\/","title":{"rendered":"IEC 60884-1 Clause 20 and 21 Three-Position Plug Socket Switch Life Tester"},"content":{"rendered":"<p>The CZKS-3 Six Positions Plug Socket Switch Life Tester is according to the IEC 60884-1 Clause 20 and 21 (GB\/T 2099.1 Clause 20 and 21), IEC 60669-1 Clause 18 and 19 (GB 16915.1 Clause 18 and 19) and IEC 61058-1 Clause 17 (GB\/T 15092.1 Clause 17) to design and manufacture. It is suitable for the breaking capacity and normal operation life test of Plugs and socket-outlets for household and similar purposes. It is also applicable to switches for household and similar fixed electrical installations for making and breaking capacity, normal operation and endurance tests. The purpose is to evaluate whether the plug socket and switch can withstand mechanical damage and electrical fatigue destruction in normal operation, and whether there is any contact adhesion or long -term closed or disconnecting phenomenon. Checking whether it has excessive wear and other harmful consequences is a special equipment for the endurance test of plug sockets and switching electrical durability.<\/p>\n<p><strong>Standard:<\/strong><br \/>\nIEC 60884-1 (GB\/T 2099.1 ) \"Spine e prese di corrente per usi domestici e similari - Parte 1: Prescrizioni generali\" Clausole 20 e 21<br \/>\nIEC 60669-1 (GB 16915.1) \"Apparecchi di comando non automatici per installazione elettrica fissa per uso domestico e similare - Parte 1: Prescrizioni generali\": Prescrizioni generali\" Clausole 18 e 19<br \/>\nIEC 61058-1 (GB\/T 15092.1) \"Interruttori per apparecchi - Parte 1: Prescrizioni generali\" Clausola 17<\/p>\n<p><strong>Specifica:<\/strong><\/p>\n<table style=\"width: 100.24%; height: 453px;\" width=\"546\">\n<tbody>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"102\"><strong>Modello LISUN<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\"><strong>CZKS-3<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"109\"><strong>CZKS-3P<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"97\"><strong>CZKS-3S<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"104\"><strong>CZKS-3A<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"102\">Stazione di lavoro<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\">2 plug socket +1 switch<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"109\">3 plug socket<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"97\">3 switch<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"104\">1 socket +2 switch<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"102\">Metodo di guida<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">Cilindro conducente, il gas deve essere preparato dal cliente: 4 ~ 6kg\/cm2<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"102\">Metodo di controllo<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">PLC + touch screen sovradimensionato<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"102\">Tempo di connessione\/disconnessione<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">0 \uff5e 99.9s\/min (adjustable)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"102\">Tempo di prova<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">0 \uff5e 999.999 volte (regolabile)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"102\">Itinerario di prova<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">Lineare: -40 ~ 110 mm (preimpostato); Rotazione: 0 \uff5e 360 \u00b0 (preimpostato)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"102\">Tasso di prova<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">Lineare: 0 \uff5e 100 mm\/s (preimpostato); Rotazione: 0 \uff5e 90\u00b0\/s (preimpostato)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"102\">Esempio di apparecchio<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">Apparecchio universale standard, che pu\u00f2 essere regolato verso l'alto e verso il basso (altre specialit\u00e0 possono essere personalizzate in base alle esigenze del cliente)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Suggerimenti facoltativi<\/strong>: When using LISUN CZKS-3 Three-Position Plug Socket Switch Life Tester, it is necessary to choose a LISUN LS-EU800W2-55L air compressor (power 800W*2, capacity 55L, speed 1380r\/min, pressure 0.7Mpa, flow 120L\/m in, 220~240V\/50Hz) or LS-US800W2-55L air compressor (power 800W*2, capacity 55L, speed 1380r\/min, pressure 0.7Mpa, flow 120L\/min, 110~120V\/60Hz).<\/p>\n<div id=\"attachment_16909\" class=\"wp-caption aligncenter\" style=\"width: 410px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-16909\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor-400x400.jpg\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor-400x400.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor-100x100.jpg 100w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor.jpg 500w\" alt=\"\" width=\"400\" height=\"400\" aria-describedby=\"caption-attachment-16909\" title=\"\"><\/p>\n<p id=\"caption-attachment-16909\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Compressore d'aria LS-EU800W2-55L<\/span><\/p>\n<\/div>\n<p><strong>Applicazione:<br \/>\n<\/strong>According to the corresponding standard requirements, the CZKS-3 Three-Position Plug Socket Switch Life Tester is equipped with the corresponding load cabinet, which can be used as a life test of plug-in sockets, buttons, switching switches, corset switches, push switching switches, rotating switches(can be customized):<br \/>\n- <strong>Applicazione tipica 1:<\/strong>\u00a0CZKS-3 with<a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/load-cabinet.html\" target=\"_blank\" rel=\"noopener\"> DFX-20 Cabina di carico di prova per lampade fluorescenti alimentate esternamente<\/a> (3 sets or 1 sets of DFX-20-3CH, can also be selected with 40A or 60A), you can perform the plug-in socket breaking capacity and normal operation test, which fully meets IEC 60884-1 Clause 20 and 21 (GB\/T2099.1 Clause20 and 21) test requirement.<\/p>\n<div id=\"attachment_14370\" class=\"wp-caption aligncenter\" style=\"width: 763px;\">\n<p><img decoding=\"async\" class=\"wp-image-14370 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-8.jpg\" sizes=\"auto, (max-width: 753px) 100vw, 753px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-8.jpg 753w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-8-400x377.jpg 400w\" alt=\"\" width=\"753\" height=\"710\" aria-describedby=\"caption-attachment-14370\" title=\"\"><\/p>\n<p id=\"caption-attachment-14370\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60884-1 Clausola 20 Capacit\u00e0 di rottura<\/span><\/p>\n<\/div>\n<div id=\"attachment_14371\" class=\"wp-caption aligncenter\" style=\"width: 728px;\">\n<p><img decoding=\"async\" class=\"wp-image-14371 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-4.jpg\" sizes=\"auto, (max-width: 718px) 100vw, 718px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-4.jpg 718w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-4-400x352.jpg 400w\" alt=\"\" width=\"718\" height=\"632\" aria-describedby=\"caption-attachment-14371\" title=\"\"><\/p>\n<p id=\"caption-attachment-14371\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60884-1 Clausola 21 Funzionamento normale<\/span><\/p>\n<\/div>\n<p>- <strong>Applicazione tipica 2:<\/strong>\u00a0CZKS-3 with <a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/load-cabinet.html\" target=\"_blank\" rel=\"noopener\">DFX-20 Cabina di carico di prova per lampade fluorescenti alimentate esternamente<\/a> (3 sets or 1 sets of DFX-20-3CH, can also be used with 40A or 60A), which can perform the endurance test of the normal operation of the switch, which fully meets the IEC 60669-1 Clause 19.1 and 19.2 ( GB\/ T16915.1 Clause 19.1 and 19.2) test requirement.<\/p>\n<div id=\"attachment_14373\" class=\"wp-caption aligncenter\" style=\"width: 690px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14373 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-4.jpg\" sizes=\"auto, (max-width: 680px) 100vw, 680px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-4.jpg 680w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-4-400x353.jpg 400w\" alt=\"\" width=\"680\" height=\"600\" aria-describedby=\"caption-attachment-14373\" title=\"\"><\/p>\n<p id=\"caption-attachment-14373\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60669-1 Clausola 19.1 Funzionamento normale<\/span><\/p>\n<\/div>\n<div id=\"attachment_14374\" class=\"wp-caption aligncenter\" style=\"width: 752px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14374 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2.jpg\" sizes=\"auto, (max-width: 742px) 100vw, 742px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2.jpg 742w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2-400x294.jpg 400w\" alt=\"\" width=\"742\" height=\"546\" aria-describedby=\"caption-attachment-14374\" title=\"\"><\/p>\n<p id=\"caption-attachment-14374\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60669-1 Clausola 19.2<\/span><\/p>\n<\/div>\n<p>- <strong>Applicazione tipica 3:<\/strong>\u00a0CZKS-3 with SBLL-3P20A <a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/test-for-switches-intended-for-self-ballasted-loads.html\" target=\"_blank\" rel=\"noopener\">Test for Switches Intended for Self-ballasted Loads<\/a> (1 sets), which can perform the endurance test of the normal operation of the switch, which is fully meet the IEC 60669-1 Clause19.3 (GB\/T16915.1 Clause19.2) test requirement.<\/p>\n<div id=\"attachment_14374\" class=\"wp-caption aligncenter\" style=\"width: 752px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14374 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2.jpg\" sizes=\"auto, (max-width: 742px) 100vw, 742px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2.jpg 742w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2-400x294.jpg 400w\" alt=\"\" width=\"742\" height=\"546\" aria-describedby=\"caption-attachment-14374\" title=\"\"><\/p>\n<p id=\"caption-attachment-14374\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60669-1 Clausola 19.2<\/span><\/p>\n<\/div>\n<p>- <strong>Applicazione tipica 4:<\/strong>\u00a0CZKS-3 with<a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/tungsten-halogen-lamp-load-cabinet.html\" target=\"_blank\" rel=\"noopener\"> DFX-WD20A Armadio di carico per lampade alogene e al tungsteno<\/a> (3 sets), which can perform the endurance test of the making and breaking capacity. It is fully meets the IEC 60669\u2013 1\u00a0 Clause 18 (GB\/T16915.1 Clause 18) requirements.<\/p>\n<div id=\"attachment_14372\" class=\"wp-caption aligncenter\" style=\"width: 750px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14372 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-6.jpg\" sizes=\"auto, (max-width: 740px) 100vw, 740px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-6.jpg 740w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-6-400x349.jpg 400w\" alt=\"\" width=\"740\" height=\"646\" aria-describedby=\"caption-attachment-14372\" title=\"\"><\/p>\n<p id=\"caption-attachment-14372\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60669-1 Making and breaking capacity<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The CZKS-3 Six Positions Plug Socket Switch Life Tester is according to the IEC 60884-1 Clause 20 and 21 (GB\/T 2099.1 Clause 20 and 21), IEC 60669-1 Clause 18 and 19 (GB 16915.1 Clause 18 and 19) and IEC 61058-1 Clause 17 (GB\/T 15092.1 Clause 17) to design and manufacture. It is suitable for the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3181,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[136],"class_list":["post-2379","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-czks-3"],"_links":{"self":[{"href":"https:\/\/www.ledtestsystem.com\/it\/wp-json\/wp\/v2\/posts\/2379","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestsystem.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestsystem.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/it\/wp-json\/wp\/v2\/comments?post=2379"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestsystem.com\/it\/wp-json\/wp\/v2\/posts\/2379\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/it\/wp-json\/wp\/v2\/media\/3181"}],"wp:attachment":[{"href":"https:\/\/www.ledtestsystem.com\/it\/wp-json\/wp\/v2\/media?parent=2379"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/it\/wp-json\/wp\/v2\/categories?post=2379"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/it\/wp-json\/wp\/v2\/tags?post=2379"}],"curies":[{"name":"parola chiave","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}