{"id":2432,"date":"2025-06-19T19:35:47","date_gmt":"2025-06-19T11:35:47","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/programmable-withstanding-voltage-insulation-test\/"},"modified":"2025-07-01T16:53:47","modified_gmt":"2025-07-01T08:53:47","slug":"test-disolement-de-tension-de-tenue-programmable","status":"publish","type":"post","link":"https:\/\/www.ledtestsystem.com\/fr\/produits\/test-disolement-de-tension-de-tenue-programmable\/","title":{"rendered":"Testeur de tension de tenue di\u00e9lectrique programm\u00e9"},"content":{"rendered":"<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Le testeur de tension de tenue et d&#039;isolement programmable LS9923 est un instrument permettant de tester les param\u00e8tres de s\u00e9curit\u00e9 \u00e9lectrique des produits \u00e9lectroniques. Il peut \u00eatre utilis\u00e9 pour tester la tension de tenue et l&#039;isolement des appareils \u00e9lectrom\u00e9nagers, des instruments et \u00e9quipements \u00e9lectroniques, des composants \u00e9lectroniques, des fils et c\u00e2bles, ainsi que d&#039;autres produits \u00e9lectriques.<\/span><\/span> <\/span><\/p>\n<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Cet instrument est dot\u00e9 d&#039;une t\u00e9l\u00e9commande, d&#039;une fonction de validation, d&#039;une alarme sonore et lumineuse et d&#039;un contr\u00f4le automatique de la dur\u00e9e du test. Facile \u00e0 utiliser, esth\u00e9tique et dot\u00e9 d&#039;une coupure rapide en cas de surintensit\u00e9, il constitue un instrument id\u00e9al pour les tests d&#039;isolement \u00e0 la tension de tenue.<\/span><\/span><\/span><\/p>\n<p><strong>Standard :<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-4706.1-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC\/EN 60335-1:2023\/GB 4706.1-2024 \"Appareils \u00e9lectrodomestiques et analogues - S\u00e9curit\u00e9 - Partie 1 : Prescriptions g\u00e9n\u00e9rales\"<\/a><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-7000.1-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60598:2024\/GB 7000-2023 \"Luminaires - Partie 1 : Prescriptions g\u00e9n\u00e9rales et essais\"<\/a><br \/>\nUL 60335:2022 \"Norme de s\u00e9curit\u00e9 des appareils m\u00e9nagers et similaires, partie 1 : Exigences g\u00e9n\u00e9rales\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-16916.1-1997-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CEI 61008-1:2012<\/a><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-16916.1-1997-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\/<\/a><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-16916.1-1997-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB-16916.1-2014<\/a><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-16916.1-1997-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\u00a0\u00ab Disjoncteurs diff\u00e9rentiels sans protection int\u00e9gr\u00e9e contre les surintensit\u00e9s pour usages domestiques et analogues (DDR) \u2013 Partie 1\u00a0: R\u00e8gles g\u00e9n\u00e9rales \u00bb<\/a><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-24344-2009-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CEI 60060-1:2010<\/a><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-24344-2009-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\/<\/a><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-24344-2009-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T 24344-2009<\/a><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-24344-2009-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\u00a0\u00ab\u00a0Techniques d&#039;essai haute tension. Partie 1\u00a0: D\u00e9finitions g\u00e9n\u00e9rales et exigences d&#039;essai\u00a0\u00bb<\/a><\/p>\n<p><strong>Sp\u00e9cification:<\/strong><\/p>\n<table style=\"width: 100.398%; height: 357px;\" border=\"1\" width=\"700\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td style=\"width: 22.441%; vertical-align: middle;\" rowspan=\"5\">\u00a0Tension de tenue<\/td>\n<td style=\"width: 31.1023%; vertical-align: middle;\">\u00a0Plage de tension de sortie<\/td>\n<td style=\"width: 48.8264%; vertical-align: middle;\">\u00a0CA\/CC 0~5,00 kV<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.1023%; vertical-align: middle;\">\u00a0Pr\u00e9cision de la tension de sortie<\/td>\n<td style=\"width: 48.8264%; vertical-align: middle;\">\u00a0\u00b1 (2%+3bits)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.1023%; vertical-align: middle;\">\u00a0Plage de courant de claquage<\/td>\n<td style=\"width: 48.8264%; vertical-align: middle;\">\u00a0CA\/CC : 0,10 \u00e0 12 mA<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.1023%; vertical-align: middle;\">\u00a0L'heure du test<\/td>\n<td style=\"width: 48.8264%; vertical-align: middle;\">\u00a00~999.9s<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.1023%; vertical-align: middle;\">\u00a0Fr\u00e9quence de sortie<\/td>\n<td style=\"width: 48.8264%; vertical-align: middle;\">\u00a050 Hz\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 22.441%; vertical-align: middle;\" rowspan=\"5\">\u00a0R\u00e9sistance d&#039;isolement<\/td>\n<td style=\"width: 31.1023%; vertical-align: middle;\">\u00a0Plage de tension de sortie<\/td>\n<td style=\"width: 48.8264%; vertical-align: middle;\">\u00a0CC 0~1,00 kV<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.1023%; vertical-align: middle;\">\u00a0Pr\u00e9cision de la tension de sortie<\/td>\n<td style=\"width: 48.8264%; vertical-align: middle;\">\u00a0\u00b1 (2%+3bits)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.1023%; vertical-align: middle;\">\u00a0Plage de r\u00e9sistance d&#039;isolement<\/td>\n<td style=\"width: 48.8264%; vertical-align: middle;\">\u00a01,0 \u00e0 2\u00a0000 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.1023%; vertical-align: middle;\">\u00a0Pr\u00e9cision de la r\u00e9sistance d&#039;isolement<\/td>\n<td style=\"width: 48.8264%; vertical-align: middle;\">\u00a0\u00b1 (5%+3bits) &lt;100M\u03a9 et \u00b1 (10%+5bits) &gt;100M\u03a9<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.1023%; vertical-align: middle;\">\u00a0L'heure du test<\/td>\n<td style=\"width: 48.8264%; vertical-align: middle;\">\u00a00~999.9s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/why-should-choose-the-programmable-withstand-voltage-tester.html\" target=\"_blank\" rel=\"noopener\">Pourquoi choisir le testeur de tension de tenue programmable ?<\/a><\/strong><br \/>\nLe testeur de tension de tenue est principalement utilis\u00e9 pour tester la tension de tenue des produits \u00e9lectroniques, des appareils \u00e9lectrom\u00e9nagers, des \u00e9quipements m\u00e9dicaux \u00e9lectroniques, des appareils d&#039;\u00e9clairage LED ou des composants \u00e9lectroniques. Il peut \u00e9galement \u00eatre utilis\u00e9 pour tester la tension de tenue di\u00e9lectrique de tout autre mat\u00e9riau isolant. Le testeur de tension de tenue traditionnel (simulateur) utilise un autotransformateur et un transformateur haute tension pour effectuer des op\u00e9rations manuelles d&#039;\u00e9l\u00e9vation et de r\u00e9duction, puis coop\u00e8re avec un mat\u00e9riel simple et un appareil de mesure pour r\u00e9aliser un testeur de tension de tenue. Il pr\u00e9sente donc plusieurs probl\u00e8mes potentiels. Le testeur de tension de tenue programmable LISUN LS9923 am\u00e9liore non seulement les probl\u00e8mes potentiels du testeur de tension de tenue traditionnel, mais int\u00e8gre \u00e9galement de nouvelles technologies de recherche et d\u00e9veloppement et de nouvelles fonctions de test.<\/p>\n<p><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-ls9923-programmable-withstanding-voltage-insulation-tester-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\">Testeur de tension de tenue et d&#039;isolement programmable LISUN LS9923 \u2013 Questions fr\u00e9quemment pos\u00e9es apr\u00e8s-vente (FAQ).<\/a><\/span><br \/>\n<\/strong>Le testeur d&#039;isolement et de tenue de tension programmable LISUN LS9923 est disponible sur le march\u00e9 depuis plus de 10 ans. L&#039;\u00e9quipe d&#039;ing\u00e9nieurs LISUN a d\u00e9j\u00e0 r\u00e9sum\u00e9 la plupart des questions et r\u00e9ponses apr\u00e8s-vente via le lien ci-dessus. Veuillez le lire attentivement\u00a0; vous pourrez r\u00e9soudre la plupart des probl\u00e8mes par vous-m\u00eame si vous avez des questions lors de l&#039;utilisation de ces instruments. LISUN continuera de mettre \u00e0 jour ces pages et vous trouverez d&#039;autres FAQ via ce lien.<\/p>","protected":false},"excerpt":{"rendered":"<p>LS9923 Programmable Withstanding Voltage &amp; Insulation Test is an instrument for testing the electrical safety parameters of electronic products. It can be used for withstand voltage and insulation testing of household appliances, electronic instruments, electronic equipment, electronic components, wires and cables and other electrical products. This instrumen has remote control, pass\/fail judgment function, sound and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3460,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[188],"class_list":["post-2432","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls9923"],"_links":{"self":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/posts\/2432","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/comments?post=2432"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/posts\/2432\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/media\/3460"}],"wp:attachment":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/media?parent=2432"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/categories?post=2432"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/tags?post=2432"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}