{"id":2338,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/goniophotometer-for-traffic-signal-lamps\/"},"modified":"2025-07-03T15:06:01","modified_gmt":"2025-07-03T07:06:01","slug":"goniophotometre-pour-feux-de-signalisation","status":"publish","type":"post","link":"https:\/\/www.ledtestsystem.com\/fr\/produits\/goniophotometre-pour-feux-de-signalisation\/","title":{"rendered":"Goniophotom\u00e8tre automatique"},"content":{"rendered":"<p>Le LSG-1950S est un syst\u00e8me de test automatique de haute pr\u00e9cision pour la distribution de l&#039;intensit\u00e9 lumineuse des luminaires de signalisation routi\u00e8re. Il peut \u00eatre utilis\u00e9 pour l&#039;\u00e9valuation et le contr\u00f4le de la qualit\u00e9. Il r\u00e9pond pleinement aux exigences. <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ECE-R65-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">Rapport final PC13050202 Oregon<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ECE-R65-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ECE-R65<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/FMVSS108-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">FMVSS108<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB13954-2004-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB13954<\/a> et <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/GB25991-2010-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB 25991<\/a> Standard.<\/p>\n<p><strong>Standard :<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ECE-R65-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ECE-R65<\/a> \"Feux sp\u00e9ciaux d'avertissement<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/FMVSS108-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">FMVSS108<\/a> \"Lampes, dispositifs r\u00e9tror\u00e9fl\u00e9chissants et \u00e9quipements associ\u00e9s. \"<br \/>\nIEC60662(<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB13954-2004-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB13954<\/a> ) \"Lampes \u00e0 vapeur de sodium haute pression\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/GB25991-2010-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB 25991<\/a> \"Projecteurs automobiles \u00e9quip\u00e9s de sources lumineuses \u00e0 DEL et\/ou de modules \u00e0 DEL<\/p>\n<p><strong>Sp\u00e9cification:<\/strong><br \/>\n\u2022 Rotations des \u00e9chantillons test\u00e9s autour de l&#039;axe vertical (-90\u00b0~+90\u00b0) et de l&#039;axe horizontal (-35\u00b0~+35\u00b0)<br \/>\n\u2022 Pr\u00e9cision de l&#039;angle : 0,1\u00b0<br \/>\n\u2022 R\u00e9solution angulaire : 0,01\u00b0<br \/>\n\u2022 D\u00e9tecteur du photom\u00e8tre\u00a0: pr\u00e9cision de classe A (classe standard) CIE<br \/>\n\u2022 Le logiciel contr\u00f4le tout gr\u00e2ce \u00e0 des capacit\u00e9s intellectuelles \u00e9lev\u00e9es et une utilisation simple.<\/p>\n<p>En s\u00e9lectionnant diff\u00e9rents sch\u00e9mas de test et dispositifs de montage, vous pouvez remplacer rapidement diff\u00e9rents \u00e9chantillons test\u00e9s.<\/p>\n<p>Le goniophotom\u00e8tre LSG-1950 est compatible avec LISUN. <a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/flashlight-photometer.html\" target=\"_blank\" rel=\"noopener\">Photom\u00e8tre \u00e0 lampe de poche PM400F<\/a> pour satisfaire pleinement aux normes suivantes\u00a0:<br \/>\n- MH\/T 6012-1999 - Feu d'obstacle pour l'aviation<br \/>\n- HB6490-1991 - Sp\u00e9cifications g\u00e9n\u00e9rales pour les feux de navigation d'a\u00e9ronefs et les feux anticollision<br \/>\n- JTT 761-2022 - Conditions techniques g\u00e9n\u00e9rales pour les aides \u00e0 la navigation lumineuses<br \/>\n\u2022 Dispositions uniformes ECER65 relatives \u00e0 l\u2019homologation des feux de signalisation sp\u00e9ciaux pour v\u00e9hicules automobiles<br \/>\n- JJF1330-2011 - Sp\u00e9cification d'\u00e9talonnage pour les appareils de mesure de l'intensit\u00e9 lumineuse effective transitoire.<\/p>\n<div id=\"attachment_10915\" class=\"wp-caption aligncenter\" style=\"width: 410px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-10915\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/06\/PM400F_AL-400x400.jpg\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/06\/PM400F_AL-400x400.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/06\/PM400F_AL-1080x1080.jpg 1080w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/06\/PM400F_AL-100x100.jpg 100w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/06\/PM400F_AL-768x768.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/06\/PM400F_AL.jpg 1200w\" alt=\"\" width=\"400\" height=\"400\" aria-describedby=\"caption-attachment-10915\" title=\"\"><\/p>\n<p id=\"caption-attachment-10915\" class=\"wp-caption-text\">Photom\u00e8tre \u00e0 lampe de poche PM400F<\/p>\n<\/div>\n<p><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lsg-1950s-goniophotometer-for-traffic-signal-lamps-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\">Goniophotom\u00e8tre LISUN LSG-1950S pour feux de signalisation routi\u00e8re \u2013 Foire aux questions (FAQ) apr\u00e8s-vente<\/a><\/span><br \/>\n<\/strong>Le goniophotom\u00e8tre LISUN LSG-1950S pour feux de signalisation est commercialis\u00e9 depuis plus de 10 ans. L&#039;\u00e9quipe d&#039;ing\u00e9nierie du service apr\u00e8s-vente de LISUN a compil\u00e9 la plupart des questions et r\u00e9ponses les plus fr\u00e9quentes (FAQ) et est disponible via le lien ci-dessus. Veuillez consulter attentivement ce document\u00a0; vous pourrez ainsi r\u00e9soudre la plupart des probl\u00e8mes que vous pourriez rencontrer lors de l&#039;utilisation de l&#039;appareil. LISUN continuera de mettre \u00e0 jour cette page et d&#039;autres FAQ sont disponibles via ce lien.<\/p>","protected":false},"excerpt":{"rendered":"<p>LSG-1950S is a high accuracy automatic test system for luminous intensity distribution of traffic signal luminaires and it can be applied to quality evaluation and quality control. It fully meets the Final Report PC13050202 Oregon, ECE-R65, FMVSS108, GB13954 and GB 25991 Standard. Standard: ECE-R65 \u201cSpecial Warning Lights\u201d FMVSS108 \u201cLamps, re-flective devices, and associated equipment. \u201c [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":411,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[96],"class_list":["post-2338","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lsg-1950s"],"_links":{"self":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/posts\/2338","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/comments?post=2338"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/posts\/2338\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/media\/411"}],"wp:attachment":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/media?parent=2338"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/categories?post=2338"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/tags?post=2338"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}