{"id":2328,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/portable-ccd-spectroradiometer-2\/"},"modified":"2025-07-03T14:51:11","modified_gmt":"2025-07-03T06:51:11","slug":"spectroradiometre-ccd-portable-2","status":"publish","type":"post","link":"https:\/\/www.ledtestsystem.com\/fr\/produits\/spectroradiometre-ccd-portable-2\/","title":{"rendered":"Spectroradiom\u00e8tre portable"},"content":{"rendered":"<p>Le spectroradiom\u00e8tre CCD LED portable est disponible dans les versions suivantes, qui peuvent mesurer diff\u00e9rents param\u00e8tres :<strong><br \/>\n<\/strong><\/p>\n<table style=\"width: 100.373%; height: 792px;\" width=\"709\">\n<tbody>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">Mod\u00e8le LISUN<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Fonction<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">Gamme d'ondes<\/td>\n<\/tr>\n<tr style=\"height: 151px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 151px;\" width=\"111\">LMS-6000<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 151px;\" width=\"497\">\u00e9clairement, E(Fc), Ee(W\/m2), Tc (K), temp\u00e9rature de couleur corr\u00e9l\u00e9e (CCT), coordonn\u00e9es chromatiques, IRC, TM-30 (Rf, Rg), puret\u00e9, longueur d'onde de cr\u00eate, longueur d'onde dominante, demi-largeur de bande, longueur d'onde centrale, longueur d'onde centro\u00efde, diff\u00e9rence totale de couleur, diff\u00e9rence de luminosit\u00e9, degr\u00e9 rouge-vert, degr\u00e9 jaune-bleu, diff\u00e9rence CCT, diagramme SDCM, diagramme du spectre. Cliquez ici pour voir le <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000-Test-Report.pdf\" target=\"_blank\" rel=\"noopener\">Rapport d'essai du LMS-6000<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 151px;\" width=\"101\">380-780nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000C<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Param\u00e8tres LMS-6000 sans logiciel PC et TM-30 (Rf, Rg)<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">380-780nm<\/td>\n<\/tr>\n<tr style=\"height: 91px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 91px;\" width=\"111\">LMS-6000UV<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 91px;\" width=\"497\">Rayonnement UV-A, UV-B, UV-C et UV total (0,1-500 000\u03bcW\/cm\u00b2 \u00b10,01\u03bcW\/cm\u00b2), rayonnement de risque UV, spectre UV, longueur d'onde dominante, signal de cr\u00eate, longueur d'onde de d\u00e9part, longueur d'onde d'arriv\u00e9e. Veuillez cliquer ici pour voir le <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lms-6000uv-test-report.pdf\" target=\"_blank\" rel=\"noopener\">Rapport d'essai du LMS-6000UV<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 91px;\" width=\"101\">200-400nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000F<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">LMS-6000 Param\u00e8tres+Test de scintillement. Cliquez ici pour voir le <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000F.pdf\" target=\"_blank\" rel=\"noopener\">Rapport d'essai du LMS-6000F<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">380-780nm<\/td>\n<\/tr>\n<tr style=\"height: 151px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 151px;\" width=\"111\">LMS-6000L<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 151px;\" width=\"497\">Brightness (0.1-500,000cd\/m\u00b2\u00b10.1cd\/m\u00b2), fL, Tc (K), temp\u00e9rature de couleur corr\u00e9l\u00e9e Duv (CCT), coordonn\u00e9es chromatiques, CRI, TM-30 (Rf, Rg), puret\u00e9, longueur d'onde de cr\u00eate, longueur d'onde dominante, demi-bande, longueur d'onde centrale, longueur d'onde centro\u00efde, diff\u00e9rence de couleur totale, diff\u00e9rence de luminosit\u00e9, degr\u00e9 rouge-vert, degr\u00e9 jaune-bleu, diff\u00e9rence CCT, diagramme SDCM, diagramme du spectre. Cliquez ici pour voir le <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000L.pdf\" target=\"_blank\" rel=\"noopener\">Rapport d'essai du LMS-6000L<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 151px;\" width=\"101\">380-780nm<\/td>\n<\/tr>\n<tr style=\"height: 61px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 61px;\" width=\"111\">LMS-6000B<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 61px;\" width=\"497\">Param\u00e8tres LMS-6000+Irradiance pond\u00e9r\u00e9e par les risques de la lumi\u00e8re bleue selon GB\/T20145, CIE S009\/E:2002<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 61px;\" width=\"101\">350-800nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000BF<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">LMS-6000B Param\u00e8tres+Test de scintillement. Cliquez ici pour voir le <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000BF.pdf\" target=\"_blank\" rel=\"noopener\">Rapport d'essai du LMS-6000BF<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">350-800nm<\/td>\n<\/tr>\n<tr style=\"height: 91px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 91px;\" width=\"111\">LMS-6000P<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 91px;\" width=\"497\">Param\u00e8tres LMS-6000+PAR, PPFD (0.1-500,000umol\/m\u00b2.s \u00b10.01umol\/m\u00b2.s) , YPFD, rayonnement bleu-violet Eb, rayonnement jaune-vert Ey, rayonnement rouge-orange Er, rapport des rayonnements rouge et bleu Erb_Ratio. Veuillez cliquer ici pour voir le <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000P.pdf\" target=\"_blank\" rel=\"noopener\">Rapport d'essai du LMS-6000P<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 91px;\" width=\"101\">350-850nm<\/td>\n<\/tr>\n<tr style=\"height: 61px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 61px;\" width=\"111\">LMS-6000S<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 61px;\" width=\"497\">Param\u00e8tres LMS-6000P+Irradiance pond\u00e9r\u00e9e de la lumi\u00e8re bleue selon GB\/T20145, CIE S009\/E:2002<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 61px;\" width=\"101\">350-950nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000SF<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Fonctions compl\u00e8tes : Param\u00e8tres LMS-6000S+Test de scintillement. Cliquez ici pour voir le <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000SF.pdf\" target=\"_blank\" rel=\"noopener\">Rapport d'essai du LMS-6000SF<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">350-950nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000I<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Contr\u00f4le des entr\u00e9es et sorties via RS485<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">380-780nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"Rendu des couleurs des sources lumineuses LED blanches\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"M\u00e9thode de mesure et de sp\u00e9cification des propri\u00e9t\u00e9s de rendu des couleurs des sources lumineuses\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/OPTICAL-ENGINEERING-49-3-033602-2010-COLOR-QUALITY-SCALE-CQS-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">Optical-Engineering-49-3-033602<\/a> \" \u00c9chelle de qualit\u00e9 des couleurs\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEEE-2015-STANDARDS-1789-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEEE<\/a>Pratiques recommand\u00e9es pour la modulation du courant dans les LED \u00e0 haute luminosit\u00e9 afin d'att\u00e9nuer les risques pour la sant\u00e9 des t\u00e9l\u00e9spectateurs\".<\/p>\n<p><strong>Les sp\u00e9cifications du chromam\u00e8tre :<\/strong><br \/>\n- R\u00e9solution spectrale : \u00b10,2nm, Reproductibilit\u00e9 : \u00b10,5nm<br \/>\n- Pr\u00e9cision des coordonn\u00e9es chromatiques (\u0394x, \u0394y) : \u00b10.005<br \/>\n- Temp\u00e9rature de couleur corr\u00e9l\u00e9e CCT : 1, 500K ~ 100, 000K (\u00b10.6%)<br \/>\n- Plage d'\u00e9clairement : 0,1~500 000 lx (\u00b10,1 lx)<br \/>\n- \u00c9cran LCD : \u00c9cran tactile capacitif IPS haute d\u00e9finition de 5 pouces, r\u00e9solution jusqu'\u00e0 480*854<br \/>\n- Batterie Li-ion rechargeable de 4000mAh pouvant fonctionner en continu pendant 20 heures.<br \/>\n- Dimensions : 135mm*80mm*23mm<br \/>\n- Capacit\u00e9 de stockage<span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">8 Go, permet de stocker de 5000 \u00e0 100 000 rapports d'essai<\/span><\/span><\/span><br \/>\n- Connecter \u00e0 l'ordinateur via un c\u00e2ble USB. La version anglaise du logiciel peut fonctionner sur Win7, Win8, Win10, Win11.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-3689 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1.jpg\" sizes=\"(max-width: 2880px) 100vw, 2880px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1.jpg 2880w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1-400x119.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1-768x228.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1-1920x569.jpg 1920w\" alt=\"LMS-6000 Colorim\u00e8tre portable \u00e0 LED Spectroradiom\u00e8tre CCD Rapport d&#039;essai\" width=\"2880\" height=\"854\" title=\"\"><\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-new-version-lms-6000-portable-ccd-spectroradiometer-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LMS-6000 Portable CCD Spectroradiometer - Questions fr\u00e9quemment pos\u00e9es apr\u00e8s-vente (FAQ)<\/span><\/a><br \/>\n<\/strong>Le spectroradiom\u00e8tre CCD portable LISUN LMS-6000 est commercialis\u00e9 depuis plus de 10 ans. L'\u00e9quipe d'ing\u00e9nieurs LISUN a d\u00e9j\u00e0 r\u00e9sum\u00e9 la plupart des questions et r\u00e9ponses du service apr\u00e8s-vente dans le lien ci-dessus. Veuillez les lire attentivement, vous pourrez r\u00e9soudre la plupart des probl\u00e8mes par vous-m\u00eame si vous avez des questions lors de l'utilisation de l'instrument. LISUN continuera \u00e0 mettre \u00e0 jour ces pages et d'autres FAQ peuvent \u00eatre trouv\u00e9es dans ce lien.<\/p>","protected":false},"excerpt":{"rendered":"<p>The Portable CCD LED Colorimeter Spectroradiometer has the following versions which can measure different parameters: LISUN Model Function Wave Range LMS-6000 illuminance, E(Fc), Ee(W\/m2), Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, TM-30 (Rf, Rg), Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3419,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[42],"class_list":["post-2328","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-6000"],"_links":{"self":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/posts\/2328","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/comments?post=2328"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/posts\/2328\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/media\/3419"}],"wp:attachment":[{"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/media?parent=2328"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/categories?post=2328"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/fr\/wp-json\/wp\/v2\/tags?post=2328"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}