{"id":2340,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/lamp-preheat-assistant-source\/"},"modified":"2025-06-27T10:40:20","modified_gmt":"2025-06-27T02:40:20","slug":"lamp-preheat-assistant-source","status":"publish","type":"post","link":"https:\/\/www.ledtestsystem.com\/de\/produkte\/lamp-preheat-assistant-source\/","title":{"rendered":"Lampenvorw\u00e4rmhilfe"},"content":{"rendered":"<p>The LPS-3 works with HFP-800 (<a href=\"https:\/\/www.lisungroup.com\/products\/cfl-testing-instruments\/high-frequency-power-supply.html\" target=\"_blank\" rel=\"noopener\">Hochfrequenz-Netzteil<\/a>) und RB-3 (<a href=\"https:\/\/www.lisungroup.com\/products\/cfl-testing-instruments\/adjustable-resistance-ballast.html\" target=\"_blank\" rel=\"noopener\">Einstellbarer Widerstand Ballast<\/a>) to be an IEC Standard Test System which used to test the Frequency Fluorescent Lamp such as T5 Tube. Please visit this page to view <a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/how-to-measure-the-high-frequency-fluorescent-lamp.html\" target=\"_blank\" rel=\"noopener\">Wie man die Hochfrequenz-Leuchtstofflampe misst<\/a>. It is according to <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-ANSLG-C78.81-2013-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-ANSLG-C78.81<\/a> , <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-ANSLG-C82.11-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-ANSLG-C82.11<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC62776-2014-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC62776<\/a>,<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-10682-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\"> GB\/T-10682<\/a> , <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-15144-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T-15144<\/a> Standard.<\/p>\n<p><strong>Standard\uff1a<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-ANSLG-C78.81-2013-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-ANSLG-C78.81<\/a> \u201cAmerikanischer Nationalstandard f\u00fcr elektrische Lampen \u2013 Spezifikationen f\u00fcr die Chromatizit\u00e4t von Festk\u00f6rperbeleuchtungsprodukten\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-ANSLG-C82.11-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-ANSLG-C82.11<\/a> \u201cHilfsstromversorgung f\u00fcr Lampenvorw\u00e4rmung\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC62776-2014-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC62776<\/a> \u201cDoppelt gekapselte LED-Lampen zur Nachr\u00fcstung von linearen Leuchtstofflampen \u2013 Sicherheitsbestimmungen\u201d<br \/>\nIEC 60929:2015\/<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-15144-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T-15144<\/a> \u201cElektronische Vorschaltger\u00e4te f\u00fcr Leuchtstoffr\u00f6hren, die mit Wechsel- und\/oder Gleichstrom betrieben werden \u2013 Leistungsanforderungen\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60081-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60081<\/a>\u00a0(<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-10682-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T10682<\/a>) \u201cDoppelt gekapselte Leuchtstofflampen \u2013 Leistungsbeschreibung\u201d<\/p>\n<p><strong>Merkmal:<\/strong><br \/>\n\u2022 Double program controlled current power source output and easy to operate<br \/>\n\u2022 Adopt the program to control the preheat time<br \/>\n\u2022 Shows the degree directly; it is easy to read data such as preheat current and preheat time<br \/>\n\u2022 Alarm automatically if connection to the load is incorrect or something is wrong with the lamp<br \/>\n\u2022 It is according to double-ended fluorescent lamp adoptting the <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60081-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60081<\/a> (GB\/T10682) and the single-ended fluorescent lamp adoptting the <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-17262-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60901<\/a> (GB\/T17262)<\/p>\n<p><strong>Spezifikation:<\/strong><br \/>\n\u2022 Range about Double program controlled current power source output: 0~1.500A (It can be adjustable continuously)<br \/>\n\u2022 Adjustable pre-heat time for filament: 0~10.00s (It can be adjustable continuously)<br \/>\n\u2022 The accuracy of the current power source: 2mA<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HFP-800RB-3LPS-3_AL-1080x1080.jpg\" alt=\"\" width=\"1080\" height=\"1080\" title=\"\"><\/p>\n<p><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-hfp-800-high-frequency-power-supply-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\">LISUN LPS-3 Lamp Preheat Assistant Source \u2013 After-sales Frequently Asked Questions (FAQ)<\/a><\/span><br \/>\n<\/strong>LISUN LPS-3 Lamp Preheat Assistant Source were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>The LPS-3 works with HFP-800 (High Frequency Power Supply) and RB-3 (Adjustable Resistance Ballast) to be an IEC Standard Test System which used to test the Frequency Fluorescent Lamp such as T5 Tube. Please visit this page to view How to Measure the High Frequency Fluorescent Lamp. It is according to ANSI-ANSLG-C78.81 , ANSI-ANSLG-C82.11, IEC62776, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3436,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[98],"class_list":["post-2340","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lps-3"],"_links":{"self":[{"href":"https:\/\/www.ledtestsystem.com\/de\/wp-json\/wp\/v2\/posts\/2340","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestsystem.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestsystem.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/de\/wp-json\/wp\/v2\/comments?post=2340"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestsystem.com\/de\/wp-json\/wp\/v2\/posts\/2340\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/de\/wp-json\/wp\/v2\/media\/3436"}],"wp:attachment":[{"href":"https:\/\/www.ledtestsystem.com\/de\/wp-json\/wp\/v2\/media?parent=2340"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/de\/wp-json\/wp\/v2\/categories?post=2340"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestsystem.com\/de\/wp-json\/wp\/v2\/tags?post=2340"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}