Online Chat

+8615317905991

FTIR Integrating Sphere: Principles and Applications

Table of Contents

Fundamentals of Integrating Sphere Theory for Optical Radiation Measurement

The accurate measurement of optical radiation, encompassing total luminous flux, reflectance, and transmittance, is a cornerstone of quantitative photometry and radiometry. The integrating sphere, a fundamental apparatus in this domain, operates on the principle of multiple diffuse reflections to spatially integrate radiant flux. An integrating sphere is a hollow spherical cavity, whose interior is coated with a highly diffuse and highly reflective material, such as sintered polytetrafluoroethylene (PTFE) or barium sulfate (BaSO₄). When a light source is introduced into the sphere, either directly or through an entrance port, the light undergoes numerous diffuse reflections. Each reflection scatters the incident radiation uniformly across the entire interior surface.

This process of spatial integration creates a uniform radiance distribution across the sphere’s inner wall. According to the theory of integrating spheres, the irradiance on any point on the sphere wall is directly proportional to the total radiant flux entering the sphere, irrespective of the original spatial, angular, or polarization characteristics of the source. This key property allows for the precise measurement of total flux by placing a detector at a specific port, shielded from direct illumination from the source. The detector thus measures the spatially averaged radiance, which is converted into a photometric or radiometric quantity through a previously established calibration using a standard lamp of known luminous or radiant flux.

Integration of Fourier-Transform Infrared Spectrometry with Sphere Optics

Fourier-Transform Infrared (FTIR) spectrometry is a powerful analytical technique that measures the absorption, emission, or reflection of infrared light by a sample. Unlike dispersive spectrometers, FTIR instruments utilize an interferometer to encode the infrared spectrum as an interferogram, which is then Fourier-transformed to produce a high-resolution, high-signal-to-noise ratio spectrum. The marriage of FTIR spectrometry with an integrating sphere creates a uniquely capable system for measuring the total hemispherical properties of materials and light sources across the infrared spectrum.

An FTIR integrating sphere system typically replaces the standard external sample compartment of an FTIR spectrometer. The sphere is equipped with specialized ports for the FTIR beam entrance and exit, sample mounting, and the detector itself. The infrared beam from the interferometer is directed into the sphere, where it diffusely illuminates the sample. The light reflected or transmitted by the sample is then integrated by the sphere’s reflective coating. A high-sensitivity, liquid nitrogen-cooled Mercury Cadmium Telluride (MCT) or Indium Gallium Arsenide (InGaAs) detector, mounted on the sphere, collects the integrated signal. This configuration is indispensable for obtaining accurate diffuse reflectance and transmittance measurements, as it captures the entire hemispherical component of the scattered light, which a traditional specular reflectance accessory would miss.

The LPCE-2 System: Architecture and Technical Specifications

The LISUN LPCE-2 Integrated Sphere Spectroradiometer System represents a state-of-the-art solution for comprehensive photometric and colorimetric testing of light sources, particularly LEDs. The system is engineered to comply with a multitude of international standards, including CIE 177, CIE-13.3, IES LM-79-19, and ANSI C78.377.

The core architecture of the LPCE-2 system consists of a precision-machined integrating sphere, a high-performance CCD array spectroradiometer, a constant current power supply, and a computer running dedicated analysis software. The sphere is internally coated with a proprietary diffuse reflective material (MIEC), offering a stable and highly reflective surface with a reflectance factor greater than 95% across the visible spectrum. This ensures excellent spatial integration and measurement repeatability.

Key Technical Specifications:

  • Integrating Sphere Diameter: 0.3m, 0.5m, 1.0m, 1.5m, or 2.0m (selected based on source size and total flux).
  • Spectroradiometer: Wavelength range of 300-1100nm, optical resolution of ≤ 2.0nm, and high sensitivity for low-light measurement.
  • Photometric Parameters Measured: Luminous Flux (lm), Luminous Efficacy (lm/W), CCT (K), CRI (Ra), Chromaticity Coordinates (x,y u,v), Peak Wavelength, Dominant Wavelength, Spectral Power Distribution (SPD), and FWHM.
  • Power Supply: Provides stable DC power for the LED under test, with programmable current and voltage to simulate various operating conditions.

Measurement Principles for Total Luminous Flux and Spectral Power Distribution

The operational principle of the LPCE-2 system begins with calibration using a standard lamp traceable to the National Institute of Standards and Technology (NIST). The standard lamp, of known luminous flux and SPD, is operated at its specified rating inside the sphere. The spectroradiometer measures the resulting signal, and the software establishes a calibration coefficient that correlates the measured signal to the known photometric and radiometric quantities.

Once calibrated, the device under test (DUT)—for instance, an LED module—is activated within the sphere using the integrated constant current power supply. The light emitted by the DUT is integrated by the sphere, and the spectroradiometer captures the entire SPD of the integrated light. The software algorithm then applies the calibration coefficient to this measured SPD. By mathematically integrating the SPD over the visible wavelength range (typically 360-830nm) and weighting it by the CIE standard photopic luminosity function V(λ), the system calculates the total luminous flux. The same SPD data is the source for all other derived photometric and colorimetric parameters, ensuring internal consistency and high accuracy.

Applications in Solid-State Lighting and LED Manufacturing

In the Lighting Industry and LED & OLED Manufacturing, the LPCE-2 system is an essential quality control and R&D tool. Manufacturers utilize it to bin LEDs according to their photometric and colorimetric characteristics, ensuring consistency in mass production. It verifies compliance with datasheet specifications for luminous flux, efficacy, and color quality (CRI and CCT). For OLED Manufacturing, the system’s ability to measure large-area, diffuse surface sources is critical for evaluating performance. In Automotive Lighting Testing, the system is used to qualify the total light output and color of interior LED lighting, signal lamps, and daytime running lights against stringent automotive industry standards. Similarly, in Aerospace and Aviation Lighting, the system validates the performance of cockpit displays and cabin lighting, where reliability and precise color rendering are paramount for safety.

Advanced Applications in Photovoltaics and Display Technologies

Beyond traditional lighting, the principles of the integrating sphere find critical application in adjacent fields. In the Photovoltaic Industry, diffuse reflectance measurements using an FTIR integrating sphere are crucial for determining the quantum efficiency and optical losses of solar cell materials. Measuring the total hemispherical reflectance of anti-reflective coatings and substrate materials directly impacts device efficiency calculations.

In Display Equipment Testing, the integrating sphere is the preferred method for measuring the total luminous flux and uniformity of backlight units (BLUs) for LCDs and the emissive output of micro-LED and OLED displays. The sphere captures all light emitted from the display surface, providing a true measure of screen luminance and color gamut volume. For Medical Lighting Equipment, such as surgical lights and dermatological treatment devices, precise measurement of spectral irradiance and total radiant flux is necessary to ensure patient safety and treatment efficacy. The LPCE-2 system’s spectroradiometer is capable of these rigorous measurements.

Compliance and Standardization in Global Lighting Markets

A primary advantage of systems like the LPCE-2 is their design for compliance. The lighting industry is globally regulated by standards that dictate testing methodologies to ensure fair comparison between products. The LPCE-2 is explicitly designed to meet the requirements of:

  • IES LM-79-19: This is the paramount standard for the electrical and photometric testing of solid-state lighting products. It mandates the use of an integrating sphere or goniophotometer for total flux measurement under controlled thermal conditions.
  • CIE 177: Provides the reference methodology for measuring the chromaticity of white LEDs, accounting for spatial and spectral integration.
  • ANSI C78.377: Specifies the recommended chromaticity ranges for white LEDs with various correlated color temperatures (CCT).

By adhering to these standards, data generated by the LPCE-2 system is recognized and accepted by regulatory bodies, lighting energy efficiency programs (e.g., ENERGY STAR), and customers worldwide, providing manufacturers with a certified pathway to global markets.

Comparative Advantages of a Unified Sphere and Spectroradiometer System

The integration of the sphere and spectroradiometer into a single, turnkey system like the LPCE-2 offers significant advantages over bespoke setups. Firstly, it guarantees component compatibility and optimized optical coupling, which is engineered and validated by the manufacturer. This eliminates guesswork and potential errors in system alignment. Secondly, the unified software controls all aspects of the measurement process—power supply operation, spectrometer acquisition, and data analysis—streamlining workflow and minimizing operator-induced errors. The software often includes automated sequences for calibration and testing, further enhancing reproducibility. Finally, such systems are supplied with a traceable calibration and a certificate of conformity, providing an auditable trail for quality management systems like ISO 9001. This holistic approach reduces integration time, improves measurement reliability, and lowers the total cost of ownership.

FAQ Section

Q1: Why is a constant current power supply integrated into the LPCE-2 system?
The photometric output of an LED is highly sensitive to its forward current. Even minor fluctuations in drive current can cause significant variations in luminous flux and chromaticity. The integrated constant current power supply provides a highly stable, precise, and programmable current to the LED under test, ensuring that measurements are performed under consistent, repeatable, and datasheet-specified conditions. This is a mandatory requirement for standards-compliant testing like LM-79.

Q2: How does the size of the integrating sphere affect measurement accuracy?
Sphere size is selected based on the physical size and total flux of the light source under test. A fundamental rule is that the total area of the source and all baffles and ports should not exceed 5% of the sphere’s internal surface area to prevent significant perturbation of the sphere’s multiplicative constant. For a single LED chip, a smaller sphere (e.g., 0.3m) provides a higher signal-to-noise ratio. For a large LED lamp or module, a larger sphere (e.g., 1.5m or 2.0m) is necessary to meet the size and total flux capacity requirements and to manage self-absorption effects.

Q3: What is the purpose of the baffle inside the integrating sphere?
A baffle is an opaque shield coated with the same reflective material as the sphere. It is strategically positioned between the entrance port and the detector port. Its sole function is to prevent “first-strike” radiation—light traveling in a direct path from the source to the detector—from reaching the detector. The detector must only measure light that has been diffusely reflected multiple times, as this is the component that is proportional to the total integrated flux. The baffle is critical for achieving accurate and theoretically sound measurements.

Q4: Can the LPCE-2 system measure the efficacy (lm/W) of a lighting product?
Yes, efficacy is a primary measurement parameter. The system’s software calculates luminous efficacy automatically by dividing the total measured luminous flux (in lumens) by the electrical power input (in watts) to the light source. The electrical power is measured precisely by the system’s power meter, which monitors the voltage and current supplied to the device under test in real-time. This provides a direct and accurate measure of the overall energy efficiency of the product.

Leave a Message

=