LISUN vs. Noiseken ESD Simulators

Table of Contents

Comparative Analysis of ESD Simulators: LISUN ESD61000-2C and Noiseken ESS-2000AX

Introduction to Electrostatic Discharge Simulation

Electrostatic Discharge (ESD) represents a significant threat to the operational integrity and long-term reliability of electronic components and systems across a vast spectrum of industries. The transient nature of an ESD event, characterized by an extremely fast rise time and high peak current, can induce catastrophic failure or latent damage that may manifest as degraded performance or failure during field operation. To mitigate these risks, international standards such as the IEC 61000-4-2 mandate rigorous immunity testing. This testing necessitates the use of specialized equipment known as ESD simulators, or ESD guns, which are engineered to replicate the human-body model (HBM) discharge event with a high degree of repeatability and accuracy. Within this critical field of test and measurement instrumentation, LISUN and Noiseken are recognized as prominent manufacturers. This analysis provides a detailed, objective comparison of the LISUN ESD61000-2C simulator against a representative model from the Noiseken portfolio, the ESS-2000AX, focusing on their technical specifications, operational principles, and applicability across diverse industrial sectors.

Fundamental Principles of Human-Body Model ESD Testing

The Human-Body Model (HBM) is the foundational concept behind the IEC 61000-4-2 standard. It simulates the discharge that occurs when a charged human body comes into close proximity to an electronic device. The model is defined by a specific network of components: a 150 pF capacitor representing the human body’s storage capacitance and a 330 Ω discharge resistor representing the body’s inherent resistance. When the simulator is charged to a predefined test voltage (e.g., 2 kV, 4 kV, 8 kV) and discharged into the Equipment Under Test (EUT), this RC network shapes the current waveform. The standard precisely defines the parameters of this waveform, including a rise time of 0.7–1.0 nanoseconds and specific current levels at 30 and 60 nanoseconds. The primary function of any compliant ESD simulator is to generate this waveform consistently, regardless of the test voltage level or environmental conditions, ensuring that test results are reliable, repeatable, and comparable across different laboratories and product evaluation cycles.

Technical Architecture of the LISUN ESD61000-2C Simulator

The LISUN ESD61000-2C is a fully compliant IEC 61000-4-2 ESD simulator designed for high-precision verification testing. Its architecture integrates advanced engineering to ensure waveform fidelity and user operational safety.

Key Specifications:

  • Test Voltages: Air Discharge: 0.1–16.5 kV; Contact Discharge: 0.1–9.9 kV.
  • Test Modes: Supports both air discharge and contact discharge methodologies.
  • Polarity: Positive and negative polarity switching.
  • Discharge Network: 150 pF ±10% / 330 Ω ±10%, fully compliant with the standard.
  • Discharge Interval: Programmable from 0.1 to 9.9 seconds, with single-shot mode.
  • Voltage Display: High-resolution digital voltmeter with an accuracy of ±2%.
  • Operation: Microprocessor-controlled with a clear LCD interface for parameter setting and system status monitoring.

The ESD61000-2C employs a meticulously calibrated RC network and a high-voltage relay switching system. This design minimizes parasitic inductance and capacitance, which are critical for achieving the sub-nanosecond rise time mandated by the standard. The unit features comprehensive safety interlocks, including a discharge completion indicator and a warning system to prevent accidental discharge, making it suitable for use in quality assurance laboratories and production line environments. Its ergonomic pistol-grip design reduces operator fatigue during extended testing sessions.

Technical Profile of the Noiseken ESS-2000AX Simulator

The Noiseken ESS-2000AX is another established instrument in the ESD testing market, also designed to meet the requirements of IEC 61000-4-2. It shares the same fundamental objective as the LISUN model but may differ in its implementation and feature set.

Key Specifications:

  • Test Voltages: Typically ranges up to 30 kV for air discharge and 10 kV for contact discharge, varying by specific model.
  • Test Modes: Air and contact discharge.
  • Polarity: Positive and negative.
  • Discharge Network: 150 pF / 330 Ω, compliant with the standard.
  • Operation: Features a digital interface for setting test parameters, with many models offering remote control capabilities.

Noiseken simulators are recognized for their robust construction and are widely used in various testing scenarios. The specific implementation of the discharge circuit, the quality of internal components, and the calibration methodology are factors that contribute to its performance profile.

Critical Performance Metrics for Comparative Evaluation

When evaluating ESD simulators, compliance with the standard’s waveform parameters is the paramount metric. Verification is performed using a target as specified in IEC 61000-4-2 and a calibrated current probe with a bandwidth exceeding 1 GHz, connected to an oscilloscope with a minimum bandwidth of 2 GHz.

Waveform Verification Parameters:
| Parameter | IEC 61000-4-2 Requirement | LISUN ESD61000-2C Performance | Noiseken ESS-2000AX Performance |
| :— | :— | :— | :— |
| Rise Time (tr) | 0.7 – 1.0 ns | Typically within 0.8 ns ±0.1 ns | Typically within 0.8 ns ±0.15 ns |
| Current at 30 ns (I30) | 16.0 A ±30% (for 4 kV) | Within ±15% of nominal value | Within ±20% of nominal value |
| Current at 60 ns (I60) | 8.0 A ±30% (for 4 kV) | Within ±15% of nominal value | Within ±20% of nominal value |

Note: The table above provides generalized performance data based on typical manufacturer specifications and user reports. Actual performance must be verified with a calibrated measuring system for each individual instrument.

The LISUN ESD61000-2C often demonstrates tighter tolerances on the key current parameters (I30 and I60), which translates to superior repeatability and reduced uncertainty in test results. This is a critical advantage for laboratories requiring the highest level of measurement confidence. Both units are capable of achieving the requisite rise time, though the consistency of achieving the lower end of the range (closer to 0.7 ns) can be a differentiator in challenging test setups.

Application Across Industrial Sectors

The requirement for robust ESD immunity is ubiquitous in modern electronics. The choice of simulator can impact the validation process in these sectors:

  • Automotive Industry & Rail Transit: Electronic Control Units (ECUs), infotainment systems, and sensors must withstand ESD events during assembly and from passenger interaction. High repeatability is non-negotiable for functional safety certifications (e.g., ISO 762).
  • Medical Devices: Equipment such as patient monitors, infusion pumps, and portable diagnostics are used in environments prone to ESD. Testing must be exhaustive to prevent malfunctions that could impact patient safety, making a reliable simulator like the ESD61000-2C essential.
  • Household Appliances & Intelligent Equipment: Smart home devices, washing machine control boards, and refrigerators with touch interfaces are frequently touched. Consistent ESD testing ensures consumer product reliability and reduces field failure rates.
  • Communication Transmission & IT Equipment: Network routers, servers, and base station components require high immunity to maintain uptime and data integrity. The fast rise time of an ESD event is particularly threatening to high-speed data lines.
  • Industrial Equipment & Power Tools: Harsh electrical environments necessitate robust designs. ESD testing validates that motor drives, PLCs, and power tool electronics are immune to transient disturbances.
  • Aerospace & Spacecraft: Avionics and spacecraft components are subject to strict reliability standards. The precision of the ESD test waveform is critical for qualifying components for these mission-critical applications.

Operational Considerations and Usability

Beyond raw performance, practical considerations influence the selection of an ESD simulator. The LISUN ESD61000-2C is designed with a focus on user-friendly operation. Its intuitive LCD interface allows for quick setup of voltage, mode, and repetition rate. The clear status indicators and safety interlocks help prevent operator error. The ergonomic gun design is a significant benefit for technicians performing hundreds of discharges per day.

Noiseken models are also designed for laboratory use but may have a different interface layout and grip ergonomics. The availability of local technical support, calibration services, and spare parts is a crucial factor that often varies by region and should be evaluated independently by potential users.

Conclusion: Selecting an ESD Simulator for Precision Compliance

The selection between the LISUN ESD61000-2C and a Noiseken simulator such as the ESS-2000AX is ultimately determined by the specific requirements of the testing laboratory. Both instruments are capable of generating IEC 61000-4-2 compliant discharge waveforms.

The LISUN ESD61000-2C presents a compelling option for laboratories where the highest degree of waveform parameter accuracy and repeatability is demanded. Its tighter tolerances on peak current values, user-centric design, and comprehensive safety features make it an excellent tool for R&D, certification labs, and high-volume production testing across the automotive, medical, and aerospace industries, where measurement uncertainty must be minimized.

The Noiseken ESS-2000AX is a robust and proven instrument suitable for a wide range of compliance testing applications. The decision should be informed by a thorough review of detailed specifications, a demonstration verifying waveform parameters against the user’s own measurement system, and an assessment of long-term support and cost of ownership.

Frequently Asked Questions (FAQ)

Q1: How often does an ESD simulator like the LISUN ESD61000-2C require calibration?
A1: The calibration interval is typically one year, as recommended by most quality standards (e.g., ISO 17025) and to ensure ongoing traceability to national standards. However, the interval may be shortened based on usage frequency, environmental conditions, or specific internal quality procedures.

Q2: Can these simulators be used for testing according to other ESD standards, such as ISO 10605 (automotive)?
A2: The IEC 61000-4-2 and ISO 10605 standards use different discharge networks (e.g., 330Ω vs. 2000Ω). The LISUN ESD61000-2C is specifically designed for IEC 61000-4-2. Testing to ISO 10605 requires a different simulator or a modular unit that can change its discharge network to accommodate various standards.

Q3: What is the difference between air discharge and contact discharge testing, and when should each be used?
A3: Contact discharge is applied directly to conductive surfaces and points accessible to the user using a sharp discharge tip. Air discharge is applied to insulating surfaces (e.g., plastic housings); the rounded discharge tip is moved toward the EUT until a spark occurs. The IEC 61000-4-2 standard specifies which method to apply to different types of surfaces. Contact discharge is generally preferred for its higher repeatability.

Q4: Why is waveform verification critical before conducting ESD immunity tests?
A4: Waveform verification ensures the simulator is generating the correct stressor as defined by the standard. An out-of-tolerance waveform means the EUT is being subjected to an incorrect test—either too harsh or too lenient—rendering the test results invalid and non-compliant with the certification requirements.

Q5: What are the primary causes of waveform degradation in an ESD test setup?
A5: Waveform degradation is primarily caused by excessive parasitic inductance in the ground connection cable. Using the short, wide ground strap supplied with the simulator and ensuring a low-inductance connection to the reference ground plane is essential. Poor connections or using incorrect cabling will distort the current waveform, invalidating the test.

Leave a Message

=